Sign In | Join Free | My himfr.com
Home > LED Exit Emergency Light >

IP66 LED Exit Emergency Light DC12-36V For Dangerous Place

    Buy cheap IP66 LED Exit Emergency Light DC12-36V For Dangerous Place from wholesalers
     
    Buy cheap IP66 LED Exit Emergency Light DC12-36V For Dangerous Place from wholesalers
    • Buy cheap IP66 LED Exit Emergency Light DC12-36V For Dangerous Place from wholesalers
    • Buy cheap IP66 LED Exit Emergency Light DC12-36V For Dangerous Place from wholesalers

    IP66 LED Exit Emergency Light DC12-36V For Dangerous Place

    Ask Lasest Price
    Brand Name : CODT
    Model Number : EXPLOSION PROTECTION ES02 SERIES EXIT SIGN
    Certification : ATEX, IECEx,ETL,API,ABS
    Price : negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 500 pcs per day
    Delivery Time : 5-20days
    • Product Details
    • Company Profile

    IP66 LED Exit Emergency Light DC12-36V For Dangerous Place

    IP66 Emergency Exit Light for Dangerous Place ES02 SERIES EXIT SIGN

    • Certifications:

    ATEX Marking

    Ⅱ 2 G Ex db IIB+H T6 Gb 2

    Ⅱ 2 D Ex tb IIIC T70°C Db IP66

    IP66

    IECEx Marking

    Ex db IIB+H T6 Gb

    Ex tb IIIC T70°C Db

    • Standard Materials:

    Housing: Die-casting aluminum

    Indicator: Tempered glass

    Bolts: Stainless steel

    Mounting Sling: Stainless steel

    Panel: Glass

    • Key Features:

    Label content can be customizable.

    Low working wattage for energy saving.

    High leakproofness up to IP66.

    3/4"NPT or M25 conduit hubs.

    Mounting ways: pendant, wall and end bracket mountings.

    Hinged-access door.

    Optics beam angle can be wide and narrow.

    Edge-lit sign.

    Can be used outdoors.

    Various languages and exit signs are available.

    • Additional Features:

    Emergency backup battery for exit sign and spot light for contingency period of 180 minutes.

    Two top bright spot lights can be adjusted in horizontal and vertical directions.

    Long lifespan up to 50,000 hours.

    5-year warranty.

    • Installation Guidance:

    WARNING Risk of fire, electric shock or personal injury. Please turn o ffpower before installation!

    READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING. KEEP THIS INSTRUCTIONS FOR FUTURE REFERENCE.

    THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY QUALIFIED ELECTRICIAN WHO IS FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDOUS INVOLVED.

    Fixtures must be wired in accordance with the National electrical code and all applicable local codes. Proper grounding is required for safety.

    Risk of fire or electric shock. Exit light installation requires knowledge of luminaires and electrical systems. DO NOT open the enclosure when energized. DO NOT try to install if not qualified. Please contact a professional electrician.

    Risk of fire or electric shock. Suitable for wet locations. Make sure the power is o ffprior to installation.

    Risk of fire or electric shock. Suitable for non-insulated surface and frame.

    DO NOT cover fixture with insulation liner or similar material.

    DO NOT install in unstable, loose or breakable surfaces.

    DO NOT let objects impact or exert force on the surface of the fixture.

    • Catalog Number Logic:

    IP66 LED Exit Emergency Light DC12-36V For Dangerous Place

    • Dimension & Technical Data​

    EX-ES02C2 and EX-ES02C3: Junction Box or Emergency Backup Box

    IP66 LED Exit Emergency Light DC12-36V For Dangerous Place

    TypeModel NumberInput
    Junction BoxEX-ES02C2Max. AC800V CurrencyCable Cross Section: 2.5mm² 24A
    Cable Cross Section: 4.0mm² 32A
    Cable Cross Section: 6.0mm² 41A
    Cable Cross Section: 10mm² 57A
    Cable Cross Section: 16mm² 76A
    Cable Cross Section: 35mm² 125A
    Cable Cross Section: 70mm² 192A
    Cable Cross Section: 240mm² 400A
    Battery BoxEX-ES02C3
    Junction BoxEX-ES02C2
    Battery BoxEX-ES02C3

    Type A1: Luminaire

    IP66 LED Exit Emergency Light DC12-36V For Dangerous Place

    HousingModel NumberWattageLumens(Im)Input
    Small HousingEX-5W ES02AN505W650AC100-277V by driver and by IC
    EX-10W ES02AN5010W1300
    EX-1*8W ES02AN408W1040
    Big HousingEX-15W ES02A1N4015W1950DC12-48V
    EX-20W ES02A1N4020W2600
    EX-2*8W ES02A1N4016W2080
    EX-3*8W ES02A1N4024W3120

    Type A2: Luminaire + Emergency Backup Battery

    IP66 LED Exit Emergency Light DC12-36V For Dangerous Place

    HousingModel NumberWattageLumens(Im)Input
    Small HousingEX-5W ES02A2N505W650AC100-277V by driver and by IC DC12-48V
    EX-10W ES02A2N5010W1300
    EX-1*8W ES02A2N408W1040
    Big HousingEX-15W ES02A2N4015W1950
    EX-20W ES02A2N4020W2600
    EX-2*8W ES02A2N4016W2080
    EX-3*8W ES02A2N4024W3120

    Type B1: Emergency Backup + Luminaire (two pieces of spot light)

    IP66 LED Exit Emergency Light DC12-36V For Dangerous Place


    HousingModel NumberWattageLumens(Im)Input
    Big HousingEX-XXW ES02B17W-20W910-2600AC100-277V
    by driver and by ICEmergency backup
    for three hours

    Type B2: Recessed EXIT Signs

    IP66 LED Exit Emergency Light DC12-36V For Dangerous Place


    Model NumberWattageMarksInput Voltage
    EX-5W ES02B2A5WEXITAC100-277V
    by driver and by IC

    DC12-48V
    EX-5W ES02B2B5W
    EX-5W ES02B2C5W
    EX-5W ES02B2D5W
    EX-5W ES02B2E5W
    EX-5W ES02B2F5W
    EX-5W ES02B2G5W
    EX-5W ES02B2H5W
    EX-5W ES02B2I5W
    EX-5W ES02B2J5WEXIT→
    EX-5W ES02B2K5W← EXIT

    Tpye B3: Pendant EXIT Sign + Emergency Backup Battery

    IP66 LED Exit Emergency Light DC12-36V For Dangerous Place

    Model NumberWattageMarksInput Voltage
    EX-5W ES02B3A5WEXITAC100-277V
    by driver and by IC

    DC12-48V
    EX-5W ES02B3B5W
    EX-5W ES02B3C5W
    EX-5W ES02B3D5W
    EX-5W ES02B3E5W
    EX-5W ES02B3F5W
    EX-5W ES02B3G5W
    EX-5W ES02B3H5W
    EX-5W ES02B3I5W
    EX-5W ES02B3J5WEXIT→
    EX-5W ES02B3K5W← EXIT

    Type B4: Recessed EXIT Sign + Luminaire (two pieces of spot light) + Emergency Backup Battery

    IP66 LED Exit Emergency Light DC12-36V For Dangerous Place

    Model NumberWattageMarksInput Voltage
    EX-7W ES02B4A7WEXITAC100-277V
    by driver and by IC

    DC12-48V
    EX-7W ES02B4B7W
    EX-7W ES02B4C7W
    EX-7W ES02B4D7W
    EX-7W ES02B4E7W
    EX-7W ES02B4F7W
    EX-7W ES02B4G7W
    EX-7W ES02B4H7W
    EX-7W ES02B4I7W
    EX-7W ES02B4J7WEXIT→
    EX-7W ES02B4K7W← EXIT

    Type B5: Pendant EXIT Sign + Luminaire (two pieces of spot light) + Emergency Backup Battery

    IP66 LED Exit Emergency Light DC12-36V For Dangerous Place

    Model NumberWattageHeadExitMarksInput Voltage
    EX-XXW ES02B5A7W7-20W1-5WEXITAC 100-277V
    (by driver or by IC)
    DC 12-48V
    EX-XXW ES02B5B7W7-20W1-5W
    EX-XXW ES02B5C7W7-20W1-5W
    EX-XXW ES02B5D7W7-20W1-5W
    EX-XXW ES02B5E7W7-20W1-5W
    EX-XXW ES02B5F7W7-20W1-5W
    EX-XXW ES02B5G7W7-20W1-5W
    EX-XXW ES02B5H7W7-20W1-5W
    EX-XXW ES02B5I7W7-20W1-5W
    EX-XXW ES02B5J7W7-20W1-5WEXIT→
    EX-XXW ES02B5K7W7-20W1-5W← EXIT

    XX= Number “7~20”, represent how much wattage.

    Type C&D: Emergency Light

    IP66 LED Exit Emergency Light DC12-36V For Dangerous Place


    HousingModel NumberWattageEmergency TimeInput Voltage
    Model CEX-3W ES02C3W180 minsAC100-277V
    (by driver and by IC)
    EX-5W ES02C5W180 mins
    EX-10W ES02C10W180 mins
    Model DEX-3W ES02D3W180 minsAC100-277V
    (by driver and by IC)
    EX-5W ES02D5W180 mins
    EX-10W ES02D12W180 mins
    • Packing Information:
    ModelQuantity/CartonLength(cm)Width(cm)Height(cm)Net Weight(kg)Gross Weight(kg)
    ES02A1 PCS4627239.511.5
    ES02B011 PCS6651261821
    ES02B021 PCS5651261214.5
    ES02B031 PCS4651261113
    ES02B041 PCS46512610.512.5
    ES02C1 PCS4443.428.6911
    ES02D1 PCS4441.5348.810.8
    • Mounting:

    Wall Mounting with Bracket:

    IP66 LED Exit Emergency Light DC12-36V For Dangerous Place

    Wall Mounting with Arm:

    Type B5

    IP66 LED Exit Emergency Light DC12-36V For Dangerous Place

    • QA:

    Q1. Can I have a sample order for led light?

    A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.


    Q2. What about the lead time?

    A: 3-5 days for Sample preparing ,8-10 working days for mass production.


    Q3. Do you have any MOQ limit for led light order?

    A: Low MOQ, 1pc for sample checking is available.

    Quality IP66 LED Exit Emergency Light DC12-36V For Dangerous Place for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen CODT technology co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)